Dc voltage: 12V
Led operation voltage: 3 ~ 12V
Rated current: 5A
Current range: 0 ~ 5A
Rated power: 60W
Ripple & noise: 120mVp-p
Voltage adj. range: 10.8 ~ 13.2V Can be adjusted by internal potential meter SVR1
Current adj. range: -25% ~ 3%. Can be adjusted by internal potential meter SVR2
Voltage tolerance: +/- 5.0%
Line regulation: +/- 1.0%
Load regulation: +/- 2.0%
Setup, rise time: 500ms, 30ms / 230VAC 1500ms, 30ms / 115VAC at full load
Hold up time: 50ms/230VAC 16ms/115VAC at full load
Voltage range: 90 ~ 264VAC
Frequency range: 47 ~ 63Hz
Efficiency: 85%
Ac current: 1.2A/115VAC 0.7A/230VAC
Inrush current: COLD STAR 60A/230VAC
Leakage current: 0.25mA / 240VAC
Over current: 95 ~ 110%, Protection type : Constant current limiting, recovers automatically after fault condition is removed
Over voltage: 13.8 ~ 16V, Protection type : Shut down o/p voltage, re-power on to recover
Dimming control (OPTIONAL): 1 ~ 10VDC or PWM signal : 100Hz ~ 3KHz
Working temp.: -20 ~ +60C (Refer to output load derating curve)
Working humidity: 20 ~ 90% RH non-condensing
Storage temp., humidity: -40 ~ +80C, 10 ~ 95% RH
Temp. coefficient: +/- 0.03%/C (0 ~ 50C)
Vibration: 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
Safety standards: Design refer to UL1310 Class 2,TUV EN60950-1, CAN/CSA C22.2 No. 223-M91(except for 48V), EN61347-2-13; IP64 approved
Withstand voltage: I/P-O/P:3KVAC
Isolation resistance: I/P-O/P:>100M Ohms / 500VDC / 25C / 70% RH
Emi conduction & radiation: Compliance to EN55022 (CISPR22) Class B
Harmonic current: Compliance to EN61000-3-2,-3
Ems immunity: Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
Mtbf: 603Khrs min. MIL-HDBK-217F (25C)
Dimension: 181*61.5*35mm (L*W*H)
Packing: 0.4Kg
Mai multe pe site-ul producatorului Mean Well